Change Languaje

sistema

 

Article Description
Heated Humidifiers

Dual servo Humidification system “Humidem CT Dual”

 

Includes:

 

H6DD05021 Reusable Dual Temperature sensor.

 

H6DD00501. Adapter Heater wire for single heat wire circuit.

 

H6DD00502 Adapter Heater wire for double heat wire circuit.

Operation manual (Spanish)

Humidification Chambers The Humidification Chamber allows the incoming gas to increase its humidity and heat; It is designed to be used by humidifiers with a round heating stage. It is suitable to be used during mechanical ventilation, oxygen therapy or simple humidification.
Circuits

Breathing Circuits for invasive mechanical ventilation and noninvasive to deliver heat and humidity necessary for the patient and reduce condensation.

 humidem

 

 

The HUMIDEM CT DUAL Humidifier is medical equipment designed to humidify and warm the therapeutic gases supplied to Neonatal, Pediatric or Adult patient.

Incluye:

Part No. Name
 H5WW00031 Humidifier
H6DD05021 Dual Temperature Sensor
H6DD00502 Simple Adapter Tube Heater
H6DD00501 Dual Adapter Tube Heater
  Operation Manual (Spanish)

 

¿How Does CT DUAL HUMIDEM works?

 

 

 

The system carries the gas mixture by shifting the temperature and humidity of the water contained in the humidifier chamber to the patient trough the breathing circuit. Using a heater wire in the inhalation and exhalation limbs of the respiratory circuit controls the generation of condensation inside, provided the gas mixture a higher percentage of relative humidity level of the patient and eliminating the need to drain the breathing circuit in its two limbs.

 

Gas mix from the mechanical ventilator or air and oxygen source enters into the humidification chamber attached to the Dual CT Humidem which heats the inside of this in a controlled manner through the heating stage and then leads this gas through to the patient breathing circuit containing the temperature and humidity required by monitoring the temperature of distal and proximal to patient safety.

 

Using heated wire in inspiratory and expiratory limbs can control the moisture provided to the patient, thus avoiding the need to drain excess accumulated condensate in the systems with water traps.

 

 

 

funcion

 Diagram

camaras

 

 

Humidification chamber designed to concentrate the water and create steam through the heating induced by the humidifier to provide heat and moisture to the gas passing through the interior of the chamber to provide the patient with the humidity conditions and desired temperature of the gas inhaled.

 

 

Part No
 Unit Purchase Description
P6RZ00431
Part Humidification Chamber Reusable Neonatal / Pediatric.
P6RZ00161 Part  Humidification Chamber. Reusable Adult 
P5DZ00431  Part Universal Camera Disposable Neonatal / Pediatric / Adult

 

 

soporte estrella 

Star Support

For pipes:

Neonatal/Pediatric y Adult

Part No
Buy Unit Description
P5VZ00051 Part Pipe suppot star patient circuit.

 

Brazo-de-sopote

 

 Part No
Buy Unit Description
T6KK00411       Part

Support Arm for Patient Circuit

 pulmon adulto

 pulmon neonatal

        

Part No Buy Unit  Description
 P5DZ00151 Part
Adult lung test of 1 liter
 P5DZ00161 Part

Neonatal test lung 60 ml 

Patient Circuit

Descripción
 Shot Circuits
Circuit Kit Humidification Chamber
  •  Start 
  •  Prev 
  •  1  2  3 
  •  Next 
  •  End 

Page 1 of 3